Hybrid Cable for Use with Lutron® Sivoia® Systems

| Specifications | |||||
|---|---|---|---|---|---|
| Part # | Communication Elements |
Power Elements | Ground Elements |
Jacket (Type, Color) |
UL Type |
| 16/18SVA | Conductors: 4 x 18 AWG Stranded BC Insulation: PE, .015" Shield: 100% Foil with 20 AWG Drain Wire Stranded TC |
Conductors: 2 x 16 AWG Stranded BC Insulation: PVC, .015" |
Conductors: 1 x 18 AWG Stranded BC Insulation: PVC |
PVC, Blue with Red Stripe |
CL3 & CM |
| Hybrid Cable for Use with Lutron® Sivoia® Systems | |||||
| 16/18SVAP | Conductors: 4 x 18 AWG (16x30) Stranded BC Insulation: PE, .015" Shield: 100% Aluminum Polyester with 20 AWG Drain wire (10x30) TC |
Conductors: 2 x 16 AWG (26x30) Stranded BC Insulation: SGPVC, .010" |
Conductors: 1 x 18 AWG (19x30) Stranded BC Insulation: SGPVC |
Plenum PVC, Natural with Red Stripe |
CL3P or CMP |
| Hybrid Cable for Use with Lutron® Sivoia® Systems: Plenum | |||||
| Lutron® is a registered trademark of Lutron Electronics Co., Inc. Sivoia® is a registered trademark of Lutron Electronics Co., Inc. |
|||||